Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
NMR Biomed ; 36(10): e4959, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37186038

RESUMEN

In this work, we introduce a super-resolution method that generates a high-resolution (HR) sodium (23 Na) image from simultaneously acquired low-resolution (LR) 23 Na density-weighted MRI and HR proton density, T1 , and T2 maps from proton (1 H) MR fingerprinting in the brain at 7 T. The core of our method is a partial least squares regression between the HR (1 H) images and the LR (23 Na) image. An iterative loop and deconvolution with the point spread function of each acquired image were included in the algorithm to generate a final HR 23 Na image without losing features from the LR 23 Na image. The method was applied to simultaneously acquired HR proton and LR sodium data with in-plane resolution ratios between sodium and proton data of 3.8 and 1.9 and the same slice thickness. Four volunteers were scanned to evaluate the method's performance. For the data with a resolution ratio of 3.8, the mean absolute difference between the generated and ground truth HR 23 Na images was in the range of 1.5%-7.2% of the ground truth with a multiscale structural similarity index (M-SSIM) of 0.93 ± 0.03. For the data with a resolution ratio of 1.9, the mean absolute difference was in the range of 4.8%-6.3% with an M-SSIM of 0.95 ± 0.01.


Asunto(s)
Protones , Sodio , Humanos , Imagen por Resonancia Magnética/métodos , Encéfalo/diagnóstico por imagen , Algoritmos
2.
Sci Rep ; 12(1): 14156, 2022 08 19.
Artículo en Inglés | MEDLINE | ID: mdl-35986071

RESUMEN

Proton MRI can provide detailed morphological images, but it reveals little information about cell homeostasis. On the other hand, sodium MRI can provide metabolic information but cannot resolve fine structures. The complementary nature of proton and sodium MRI raises the prospect of their combined use in a single experiment. In this work, we assessed the repeatability of normalized proton density (PD), T1, T2, and normalized sodium density-weighted quantification measured with simultaneous 3D 1H MRF/23Na MRI in the brain at 7 T, from ten healthy volunteers who were scanned three times each. The coefficients of variation (CV) and the intra-class correlation (ICC) were calculated for the mean and standard deviation (SD) of these 4 parameters in grey matter, white matter, and cerebrospinal fluid. As result, the CVs were lower than 3.3% for the mean values and lower than 6.9% for the SD values. The ICCs were higher than 0.61 in all 24 measurements. We conclude that the measurements of normalized PD, T1, T2, and normalized sodium density-weighted from simultaneous 3D 1H MRF/23Na MRI in the brain at 7 T showed high repeatability. We estimate that changes > 6.6% (> 2 CVs) in mean values of both 1H and 23Na metrics could be detectable with this method.


Asunto(s)
Imagen por Resonancia Magnética , Protones , Encéfalo/metabolismo , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Magnética/métodos , Fantasmas de Imagen , Reproducibilidad de los Resultados , Sodio/metabolismo
3.
Magn Reson Imaging ; 87: 157-168, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-35031443

RESUMEN

We present a method to correct artifacts typically present in images acquired in field-cycled MRI experiments under poor magnetic field spatial-homogeneity and time-stability conditions. The proposed method was tested in both simulated and experimental data. The experiments were performed using a fast field-cycling MRI relaxometer of own design, based on a current-driven variable-geometry electromagnet. Current instability-induced artifacts in the images were mitigated through a phase correction array resulted from entropy and background minimization. Image distortions due to magnetic field inhomogeneity were compensated through two different approaches, involving a previous determination of the magnetic field homogeneity-map, or an experimental protocol where two images are acquired with inverted readout gradient polarity. Results show that images acquired at extreme conditions can be successfully improved, thus strengthening the possibilities for both low-cost MRI devices and faster field-switched MRI systems.


Asunto(s)
Procesamiento de Imagen Asistido por Computador , Imagen por Resonancia Magnética , Algoritmos , Artefactos , Procesamiento de Imagen Asistido por Computador/métodos , Campos Magnéticos , Imagen por Resonancia Magnética/métodos , Imanes , Fantasmas de Imagen
4.
J Magn Reson ; 311: 106682, 2020 02.
Artículo en Inglés | MEDLINE | ID: mdl-31923764

RESUMEN

We present a fast field-cycling NMR relaxometer with added magnetic resonance imaging capabilities. The instrument operates at a maximum proton Larmor frequency of 5 MHz for a sample volume of 35 mL. The magnetic field homogeneity across the sample is 1400 ppm. The main field is generated with a notch-coil electromagnet of own design, fed with a current whose stability is 220 ppm. We show that images of reasonable quality can still be produced under such conditions. The machine is being designed for concept testing of the involved instrumentation and specific contrast agents aimed for field-cycling magnetic resonance imaging applications. The general performance of the prototype was tested through localized relaxometry experiments, T1-dispersion weighted images, temperature maps and T1-weighted images at different magnetic field intensities. We introduce the concept of positive and negative contrast depending on the use of pre-polarized or non-polarized sequences. The system is being improved for pre-clinical studies in small animals.


Asunto(s)
Imagen por Resonancia Magnética/instrumentación , Tejido Adiposo/diagnóstico por imagen , Algoritmos , Animales , Temperatura Corporal , Bovinos , Campos Electromagnéticos , Diseño de Equipo , Procesamiento de Imagen Asistido por Computador , Imagen por Resonancia Magnética/métodos , Imanes , Músculo Esquelético/diagnóstico por imagen , Fantasmas de Imagen , Relación Señal-Ruido
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...